1445 'Current controller'

  • Incorrect parameter setting for current

Device

 

Description

 

Class

Error

Drive Behaviour

 

Device Behaviour

System run-up aborted

Additional Error Information (AMK Service)

 

Info 1

0

Kpi in Q controller not workable
1 Kii in Q controller not workable
3 Kpi in D controller not workable
4 Kii in D controller not workable
5

"ID34151 Kp current Q" = 0;

"ID34152 Kp current D" ≠ 0

6

Current adaptation slope Kpi in Q controller too large

7

Current adaptation slope Kii in Q controller too large

8

Application threshold current adaptation ID34177 'Lower threshold current adaption'> ID34178 'Upper threshold current adaption'

100

Model-based current controller is not possible. Only for synchronous machines

Gerät

KU- / KW-R03

  Info 1 2

"ID34051 Kp current D" = 0;

"ID34052 TN current D" ≠ 0

Error Removal

Recheck parameters:

  • ID34051 'Current path D proportional gain KP'
  • ID34052 'Current path D integral-action time TN'
  • ID34151 'Current path Q proportional gain KP'
  • ID34152 'Current path D proportional gain KP'
  • ID34177 'Lower threshold current adaption'
  • ID34178 'Upper threshold current adaption'
  • ID34179 'Gradient path Q proportional gain'
  • ID34180 'Gradient path Q integral-action time'

Info 1 = 100: Deactivate model-based current control

  • ID32773 'Service bits' bit 27