2320 'EF inactive'

  • Output stage enabling (EF) inactive with controller enable RF active

Device

 

Description

 

Class

 

Drive Behaviour

Coast to stop

Device Behaviour

Single treatment

Additional Error Information (AMK Service)

 

 

 

 

Error Removal

Check EF

 

  • Output stage enabling (EF) inactive with controller enable RF active / STO active

Device

KW-R06 / -R07 / -R16 / -R17 / -R24 / -R24-R / -R25 / -R26 / -R27 / iX / iC / iDT5 / / iX-R3 / iC-R3 / iDT5-R3 / ihX

Description

 

Class

Error

Drive Behaviour

Coast to stop

Device Behaviour

-

Additional Error Information (AMK Service)

 

Info 1

1

Info 2

0

 

1

 

2

 

3

 

4

 

5

Monitoring function runs system-internally with the fastest cycle time. The message can also occur in systems without safety functionality and suppress known messages with Info 2 = 0, 1 or 2.

Error Removal

Check EF / STO

Check Safety functionality