2560 'System diagnostics'
|
|||||||||
Device |
A7 |
||||||||
Description |
|
||||||||
Class |
|
||||||||
Drive Behaviour |
|
||||||||
Device Behaviour |
|
||||||||
Additional Error Information (AMK Service) |
|||||||||
|
Info 1 (ErrorCode) |
1 |
Parsing error: Unable to find node 'VendorID'
|
||||||
|
|
2001 |
In 'ECAT_libraryConfigure', 'memoryAlloc', 'memoryFree', 'openFile' or 'checkFile' are ZERO
|
||||||
|
|
2002
|
Library has been initialized. Call 'ECAT_libraryConfigure'
|
||||||
|
|
2003 |
Unable to allocate memory for EtherCAT master
|
||||||
|
|
2004 |
Unable to parse ENI file
|
||||||
|
|
2005 |
Master configuration failed with error code
|
||||||
|
|
2006 |
Trying to configure master with an inconsistent configuration state
|
||||||
|
|
2008 |
Unable to allocate slaves queue (enhanced configuration)
|
||||||
|
|
2009 |
Unable to allocate memory for acyclic frame
|
||||||
|
|
2011 |
Parsing error: Variable name or product revision length exceeds maximum length
|
||||||
|
|
2012 |
Parsing error: 'AutoIncAddr', 'SlavePhysAddr' and 'IdentificationAdo' are not configured
|
||||||
|
|
2013 |
Parsing error: Unable to find node 'AutoIncAddr' or 'Value'
|
||||||
|
|
2014 |
Parsing error: 'AutoIncAddr', 'SlavePhysAddr' and 'IdentificationAdo' are not configured
|
||||||
|
|
2016 |
Parsing error: Unable to find node 'ProductCode'
|
||||||
|
|
2017 |
Parsing error: Unable to find node 'RevisionNo'
|
||||||
|
|
2018 |
Parsing error: Unable to find node 'SerialNo'
|
||||||
|
|
2019 |
Unable to add slave to network configuration
|
||||||
|
|
2020 |
Parsing error: Unable to add Tx PDO
|
||||||
|
|
2021 |
Parsing error: Unable to add Rx PDO
|
||||||
|
|
2022 |
Parsing error: Unable to find node 'Ado'
|
||||||
|
|
2023 |
Unable to allocate slaves queue
|
||||||
|
|
2024 |
Master configuration failed due to Identification ADO duplication [ADO %d, Value %d]
|
||||||
|
|
2024 (E) |
Master configuration failed due to duplicated identification Ado
|
||||||
|
|
2025 |
Parsing error: Unable to find node 'Info'
|
||||||
|
|
2026 |
Parsing error: Unable to find node 'Cmd'
|
||||||
|
|
2027 |
Parsing error: Unable to find node 'Physics'
|
||||||
|
|
2028 |
Unable to open ENI file
|
||||||
|
|
2030 |
Unable to find ENI file
|
||||||
|
|
2031 |
In 'ECAT_masterCreate', 'sampleTime' parameter is too big compared to network reset timeout
|
||||||
|
|
2032 |
In 'ECAT_masterCreate', invalid 'sampleTime' parameter
|
||||||
|
|
2033 |
Unable to add detected slave due to the given error code
|
||||||
|
|
3000 |
Number of detected slaves differs from the expected number of slaves
|
||||||
|
|
3000 (E) |
|
||||||
|
|
3001 |
Current network state and expected network state are different
|
||||||
|
|
3002 |
Current network state and expected network state are different
|
||||||
|
|
3003 |
Current network state and expected network state are different (network state is unknown)
|
||||||
|
|
3004 |
Invalid parent Rx port
|
||||||
|
|
3005 |
Invalid parent Tx port
|
||||||
|
|
3006 |
Master failed to calculate propagation delays (invalid values are provided in 'ErrorInfo1' and 'ErrorInfo2')
|
||||||
|
|
3007 |
Autotopology detection disabled, but position is unknown for slave with the given physical address
|
||||||
|
|
3011 |
Network DC (DIstributed Clock) not synchronized
|
||||||
|
|
3012 |
Master stopped
|
||||||
|
|
3013 |
Service to check network status failed
|
||||||
|
|
3014 |
Failed to read a register in the initialize phase
|
||||||
|
|
3015 |
Prepare DC internal service failed
|
||||||
|
|
3016 |
Master service to check the network state failed! (An internal register access service failed)
|
||||||
|
|
3017 |
Internal error: Can not append service
|
||||||
|
|
3018 |
Unable to find slave's parent to calculate propagation delay
|
||||||
|
|
3019 |
Slaves are not synchronized
|
||||||
|
|
3021 |
Master stopped in fatal state. This error indicates that a fatal error happened or the user has invoked 'ECAT_masterSetComError()' per to stop the master
|
||||||
|
|
3022 |
Current network state and expected network state are different (network state is unknown)
|
||||||
|
|
4000 |
Slave is missing
|
||||||
|
|
4001 |
Invalid frames received
|
||||||
|
|
4001 (E) |
Invalid frames received
|
||||||
|
|
4002 |
On port X detected x forwarded Errors
|
||||||
|
|
4003 |
SDO init cmd failed
|
||||||
|
|
4004 |
EtherCAT transition failed (timeout)
|
||||||
|
|
4005 |
EtherCAT transition failed (validation failed)
|
||||||
|
|
4007 |
Slave has been configured to use DC (Distributed Clock), but does not support DC
|
||||||
|
|
4008 |
Slave [PhysAddr] uncontrolled state change from 'oldState' to 'newState'
|
||||||
|
|
4008 (E) |
SoE init cmd failed
|
||||||
|
|
4009 |
No answer from slave, therefore is missing
|
||||||
|
|
4010 |
Inconsistent link status on the given port
|
||||||
|
|
4010 (E) |
Inconsistent port status
|
||||||
|
|
4011 |
Inconsistent link status on the given port (should be closed)
|
||||||
|
|
4011 (E) |
Inconsistent port status on the given port (should be closed)
|
||||||
|
|
4012 |
EtherCAT reset failed with the given AL status code
|
||||||
|
|
4013 |
Internal register access service failed (AL control)
|
||||||
|
|
4014 |
Internal register access service failed (AL status)
|
||||||
|
|
4016 |
Internal register access service failed (DL status)
|
||||||
|
|
4017 |
Wrong VendorID detected
|
||||||
|
|
4018 |
Wrong Product ID detected
|
||||||
|
|
4019 |
Detected xx Errors on the EtherCAT processing unit
|
||||||
|
|
4020 |
Slave has been configured to use DC, but DC has been disabled in EEPROM
|
||||||
|
|
4021 |
Error reordering slaves
|
||||||
|
|
4022 |
Master stopped in fatal state
|
||||||
|
|
4023 |
Calculated delay exceeds cycle time
|
||||||
|
|
4024 |
Failed to get slave's parent
|
||||||
|
|
4026 |
SDO write error: Slave does not support CoE protocol
|
||||||
|
|
4028 |
SDO read error: Slave does not support CoE protocol
|
||||||
|
|
4029 |
A CoE service otification has been received, but the service is not supported
|
||||||
|
|
4030 |
Prepare DC internal service failed
|
||||||
|
|
4031 |
The slave set up the EtherCAT error flag
|
||||||
|
|
4032 |
Internal slave state machine has been stopped to a specific state due to an error
|
||||||
|
|
4033 |
Port must be connected to the given remote slave
|
||||||
|
|
4034 |
Port must be connected to the master
|
||||||
|
|
4035 |
Port number should be closed
|
||||||
|
|
4036 |
Failed to read station physical address
|
||||||
|
|
4037 |
On port x detected x link lost events
|
||||||
|
|
4038 |
Port management error
|
||||||
|
|
4039 |
Port management error
|
||||||
|
|
4040 |
Internal error: While reading SDO, Rx buffer pointer is ZERO
|
||||||
|
|
4041 |
Internal error: While reading fragmented SDO, rx buffer pointer is ZERO
|
||||||
|
|
4042 |
Slave-to-slave communication failed with the given error code
|
||||||
|
|
4043 |
SDO read failed with the abort code returned by another error message
|
||||||
|
|
4043 (E) |
SDO read failed. This message provides the abort error code
|
||||||
|
|
4044 |
Address read from register differs from configured station address
|
||||||
|
|
4045 |
Slave-to-slave communication request, but destination slave does not exist
|
||||||
|
|
4046 |
Slave-to-slave communication request, but destination slave does not support mailbox
|
||||||
|
|
4047 |
Failed to append slave-to-slave communication message
|
||||||
|
|
4049 |
SoE read error: slave does not support SoE protocol
|
||||||
|
|
4050 |
SoE write error: slave does not support SoE protocol
|
||||||
|
|
4051 |
FoE error: slave does not support FoE protocol
|
||||||
|
|
4052 |
EoE init cmd failed
|
||||||
|
|
4053 |
FoE init cmd failed
|
||||||
|
|
4054 |
FoE mismatched packet number detected
|
||||||
|
|
4055 |
EoE service initialization failed
|
||||||
|
|
4056 |
EoE send packet failed
|
||||||
|
|
4057 |
EoE mismatched fragment number detected
|
||||||
Error Removal |
|