2585 'System diagnostics'
|
|||
Device |
|
||
Description |
|||
Class |
|||
Drive Behaviour |
|||
Device Behaviour |
System run-up aborted |
||
Additional Error Information (AMK Service) |
|||
Info 1 | 6 | "ID5 Minimal feedback acquisition time" from slave is not available for time slot calculation | |
20 | "ID3 Drive transmission reaction time" from slave is not available for time slot calculation | ||
25 | "ID88 Recovery time receive-receive" from slave is not available for time slot calculation | ||
29 | "ID2 SERCOS cycle time" is too short | ||
31 | "ID90 Command value copytime" from slave is not available for time slot calculation | ||
44 | "ID4 Transmit/receive time" from slave is not available for time slot calculation | ||
45 | "ID96 Slave identifier (SKLN)" from slave is not available for time slot calculation | ||
46 | "ID87 Recovery time transmit-transmit" from slave is not available for time slot calculation | ||
80 | Timeout | ||
533 | Invalid MDT length in configuration file | ||
534 | Invalid AT length in configuration file | ||
536 | Invalid "ID2 SERCOS cycle time" | ||
537 | Invalid "ID1 NC cycle time" | ||
538 | Internal error | ||
539 | Internal error | ||
540 | Internal error | ||
541 | Internal error | ||
543 | Too much cyclic data in SERCOS cycle | ||
544 | Too many telegrams in SERCOS cycle | ||
Error Removal |
|