2699 'System diagnostics'
|
|||
|
Device |
|
||
|
Description |
|||
|
Class |
|||
|
Drive Behaviour |
Controlled braking | ||
|
Device Behaviour |
System run-up aborted |
||
|
Additional Error Information (AMK Service) |
|||
|
Info 1 |
4 |
RAM-check error | |
| 10 | Watchdog or time level error | ||
| 12 | User stack error | ||
| 13 | System stack overflow | ||
| 14 | System stack underflow | ||
| 15 | Controller error | ||
| 20 | Fast function overflow | ||
| 30 | Initialization - Software error | ||
| 31 | Initialization - error while data read | ||
| 32 | Initialization - too much FCT instances | ||
| 33 | Initialization - no FCT instance | ||
| 34 | Initialization - error while data write "ID30 Softwareversion" | ||
| 35 | Initialization - invalid bus use "ID34143 Usage port" | ||
| 36 | Error while clock initialization | ||
| 37 | FCT initialization – invalid CPLD version (2 FCT) | ||
| 38 | FCT initialization – writing error Routing "ID32944 SYADR" | ||
| 39 | FCT initialization – more than one synchronization source | ||
|
Error Removal |
|
||