3585 'System diagnostics: Special software message'

  • CAN bus: Error during initialization

Device

FSE

Description

 

Class

Error

Drive behaviour

System run-up aborted / Coast to stop

Device behaviour

 

Additional information (Info AMK service)

 

Info1

1

Info2 3
Info3 1

Upper voltage limit ID32798-3 < Lower voltage limit ID32798-4

2 Upper voltage limit ID32798-3 too large or lower voltage limit ID32798-4 too small
8

Incorrect settings Voltage limiter ID32798-3 < ID32798-7

or ID32798-4 > ID32798-10

2
Info2 1
Info3 2 Limits Torque reduction Temperature IGBT interchanged ID32798-8 > = ID32798-9
3 Limits Torque reduction Temperature Motor interchanged ID32798-11> = ID32798-12
4

Limits Torque reduction Temperature inverter interchanged ID32798-5> = ID32798-6

Error removal

  • Restart device
  • AMK service
  • Error message Motor Controller

Device

MCE

Description

 

Class

Error

Drive behaviour

Coast to stop

Device behaviour

 

Additional information (Info AMK service)

 

Info1

1

Info2 3
Info3 1

Upper voltage limit < lower voltage limit

2 P(motor) < 0
3 P(generator) < 0
4

Sign error of torque limit from calculation

5 0 V > Uz > 1000 V
6 -300 kW > motor shaft power > 300 kW
7

Error in quadrant determination

8

Faulty settings of voltage limitation

2

Faulty parameterization

Info2 1

I2t derating settings

3

Error during operation

Info2 2
Info3 2

Invalid system status automat

3

Monitoring output values

4

Faulty parameterization

Info2 4
Info3 1 Number of pulses = 0
5

Error during operation

Info2 1

Error asynchronous data storage

7
Info2 1
Info3 1 ID32798-10: 'MCE operation mode' not defined
2 ID32798-32: 'Direction forward' not defined
3 Plausibility accelerator
4 Parameter accelerator
9

Error during operation

Info2 1

Toggle bit error

10

Error during system check of the inverter

Info2 1

Analog 1

2 Analog 2
3 BI1
4 BI2
5 BI3
6 Speed difference
7 Pulse encoder input
11

Error on inactive switching off of terminal 15

Info2 1

No switching off after end of 'Switch-off time'

Error removal

  • Check parameterization
  • Restart device
  • Info1 = 11:

Software used with MCE hardware:
Internal hardware error; please contact AMK service

Software used with KW hardware:
External hardware error; please check wiring

  • Fault monitoring power supply

Device

ZWR

Description

NA protection device -A3 has tripped

Class

Error

Device Behaviour

Automatic error reset and switch back on

Additional Error Information (AMK Service)

 

 

 

 

Error Removal

  • Check mains conditions
  • Check configuration NA device -A3