3586 'System diagnostics: Special software message'

  • CAN bus: Error during initialization

Device

FSE

Description

 

Class

Error

Drive behaviour

System run-up aborted

Device behaviour

 

Additional information (Info AMK service)

 

Info1

0

Invalid CAN configuration mode (ID34091-2)
1

Configured index (ID) not found

2 Invalid signal type
3 Length of the configuration does not match the selected messages and signals
4

Invalid transmission rate

5 CAN module error

Error removal

  • Restart device
  • AMK service
  • Error messages of CAN communication

Device

MCE

Description

 

Class

Error

Drive behaviour

Coast to stop

Device behaviour

 

Additional information (Info AMK service)

 

Info1

0

Memory error

1

Module command error

2

Invalid value in ID34028 'BUS output rate'

3 Invalid value in ID34024 'BUS transmit rate'
4 Error during access CAN
5

Error in message configuration (ID34036 'CCB-File')

Error removal

  • Check parameters
  • Restart device
  • Fault BUS

Device

ZWR

Description

Fieldbus interruption

Class

Error

Device Behaviour

Automatic error reset and switch back on

Additional Error Information (AMK Service)

 

 

 

 

Error Removal

  • Check bus wiring
  • Check inverter -U1
  • Check control unit -A1