Binary inputs/outputs
API variable name |
CAN Index [hex] |
CAN
|
Copy- |
Application |
---|---|---|---|---|
bySystemIn |
2060 |
00 |
Tx |
The image of “binary inputs BE1, BE2 and BE3 is sent |
bySystemOut |
2070 |
00 |
Rx |
The image of “binary outputs” is received to issue on binary outputs BA1, BA2 and BA3 of the controller card 1) |
byInp1Byte0 |
6000 |
01 |
Tx |
The image of 1 byte „”binary inputs“ is copied to the binary input port 1 (ID32873-ID32881) |
byOutp1Byte0 |
6200 |
01 |
Rx |
The incoming byte “binary outputs image” are issued on the binary outputs (e.g. I/O option card KU- or KW-EA2 in slot 1. A1...A8 are controlled by the variable byOutp1Byte0. 2) |
1) binary outputs can be controlled by API variables if they are not used by the basic system. The following parameter setting is necessary: ID32864=0 output port address 3