Binary inputs/outputs

API variable name

CAN Index [hex]

CAN
Sub-Index [hex]

Copy-
direction

Application

bySystemIn

2060

00

Tx

The image of “binary inputs BE1, BE2 and BE3 is sent

bySystemOut

2070

00

Rx

The image of “binary outputs” is received to issue on binary outputs BA1, BA2 and BA3 of the controller card 1)

byInp1Byte0

6000

01

Tx

The image of 1 byte „”binary inputs“ is copied to the binary input port 1 (ID32873-ID32881)

byOutp1Byte0

6200

01

Rx

The incoming byte “binary outputs image” are issued on the binary outputs (e.g. I/O option card KU- or KW-EA2 in slot 1. A1...A8 are controlled by the variable byOutp1Byte0.  2)

 

1) binary outputs can be controlled by API variables if they are not used by the basic system. The following parameter setting is necessary: ID32864=0 output port address 3

2) binary outputs can be controlled by API variables if they are not used by the basic system. The following parameter setting is necessary: ID32846=0 output port address 1