Mains filter AF 15-SI, AF 45-SI, AF 60-SI, AF 90-S, AF 180-S and AF 270-S
Designation |
AF 15-SI |
AF 45-SI |
AF 60-SI |
AF 90-S |
---|---|---|---|---|
Nominal voltage |
3 x 480 V |
|||
Nominal current |
3 x 15 A |
3 x 45 A |
3 x 60 A |
3 x 90 A |
Supply voltage (Logic supply) |
- |
24 VDC 0,25 A |
||
Overload factor |
4 x IN for 10 s |
4 x IN for 10 s |
5 x IN for 10 s |
2 x IN for 10 s |
Leakage current |
< 100 mA1) |
|||
Power loss |
53 W |
140 W |
155 W |
210 W |
Protection class |
IP 20 |
|||
Weight |
7.5 kg |
11.5 kg |
14.5 kg |
15 kg |
Dimensions |
83 x 205 x 320 |
165 x 218 x 347 |
165 x 218 x 347 |
174.5 x 260 x 340 |
AMK part no. |
O915 |
O927 |
O940 |
O825 |
1) |
According to norm IEC 950 for symmetrical TT or TN networks For network switch on and switch off or line unbalance leakage currents greater than 800 mA can occur. |
Designation |
AF 180-S |
AF 270-S |
---|---|---|
Nominal voltage |
3 x 480 V |
|
Nominal current |
3 x 180 A |
3 x 270 A |
Supply voltage (Logic supply) |
24 VDC 0.5 A |
24 VDC 0.7 A |
Overload factor |
1.67 x IN for 10 s |
1.78 x IN for 10 s |
Leakage current |
< 100 mA1) |
|
Power loss |
370 W |
500 W |
Protection class |
IP 20 |
|
Weight |
19 kg |
73 kg |
Dimensions |
174.5 x 310 x 400 |
Wall mounting 349 x 300 x 454
Floor mounting2) 380 x 305 x 460 |
AMK part no. |
O812 |
O946 |
1) |
According to norm IEC 950 for symmetrical TT or TN networks For network switch on and switch off or line unbalance leakage currents greater than 800 mA can occur. |
2) |
Foot angle required (option 47869) |