Status LEDs
|
LED |
Class |
Status |
Note |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
H2 |
Drive status |
Green |
System Ready (SBM) |
||||||||||||||
|
Green flashing |
Drive under control (SBM and QRF) |
||||||||||||||||
|
Orange flashing |
Warning occurs during active controller enable |
||||||||||||||||
|
Orange |
Warning occurs during inactive controller enable / flash mode |
||||||||||||||||
|
Red |
Error with reaction depending on the error number |
||||||||||||||||
|
H3 |
Bus status (EtherCAT) |
Off |
Initialisation |
||||||||||||||
|
Green flashing |
Pre-operational |
||||||||||||||||
|
Green single flash |
Safe-operational |
||||||||||||||||
|
Green |
Operational |
||||||||||||||||
|
Red flashing |
Configuration error |
||||||||||||||||
|
Red flashing (1 time) |
Error-dependent switch back to the Operational, Safe-operational, Pre-operational or Initialising states |
||||||||||||||||
|
H4 |
Ethernet bus [X85] |
Off |
No connection |
||||||||||||||
|
Green |
Link connection |
||||||||||||||||
|
Flashing |
Link/Activity – connection and data exchange |
||||||||||||||||
|
H5 |
Ethernet bus [X86] |
Off |
No connection |
||||||||||||||
|
Green |
Link connection |
||||||||||||||||
|
Flashing |
Link/Activity – connection and data exchange |
||||||||||||||||
|
H6 |
Functional Safety |
|
|||||||||||||||
| blinking: | TEin = 200 ms, TAus = 200 ms (2,5 Hz) |
| single flash: | TEin = 200 ms, TAus = 1000 ms (0,83 Hz) |