DC fuses and fuse holders
Designation |
AMK part no. |
Description |
---|---|---|
FWP-30A14 |
206048 |
DC fuse 30 Aeff from the company Cooper Bussmann, type FWP-30A14F Dimensions: 14 x 51 mm Rated voltage: 800 V DC Operating class: aR The DC fuse can be used for the following loads: 1) Continuous rated current for DC bus IDC, RMS: 8.5 Aeff Maximum current for DC bus Imax, 2 times overload, 1 second: 17 A |
FWP-40A14F |
205826 |
DC fuse 40 Aefffrom the company Cooper Bussmann, type FWP-40A14F Dimensions: 14 x 51 mm Rated voltage: 800 V DC Operating class: aR The DC fuse can be used for the following loads: 1) Continuous rated current for DC bus IDC, RMS: 13.5 Aeff Maximum current for DC bus Imax, 2 times overload, 1 second: 27 A |
FWP-50A14F | 206047 |
DC fuse 50 Aeff from the company Cooper Bussmann, type FWP-50A14F Dimensions: 14 x 51 mm Rated voltage: 800 V DC Operating class: aR The DC fuse can be used for the following loads: 1) Continuous rated current for DC bus IDC, RMS: 20.5 Aeff Maximum current for DC bus Imax, 2 times overload, 1 second: 41 A |
fuse holder 14 x 51 mm | 205829 |
Fuse holder 14 x 51 mm for hat rail mounting |
1) |
The actual current value at which the DC fuse triggers, depends on factors such as temperature, duty cycle, the terminal cross sections and can be significantly below the rated value of the fuse. |