DC fuses and fuse holders

Designation

AMK part no.

Description

FWP-30A14

206048

DC fuse 30 Aeff from the company Cooper Bussmann, type FWP-30A14F

Dimensions: 14 x 51 mm

Rated voltage: 800 V DC

Operating class: aR

The DC fuse can be used for the following loads: 1)

Continuous rated current for DC bus IDC, RMS: 8.5 Aeff

Maximum current for DC bus Imax, 2 times overload, 1 second: 17 A

FWP-40A14F

205826

DC fuse 40 Aefffrom the company Cooper Bussmann, type FWP-40A14F

Dimensions: 14 x 51 mm

Rated voltage: 800 V DC

Operating class: aR

The DC fuse can be used for the following loads: 1)

Continuous rated current for DC bus IDC, RMS: 13.5 Aeff

Maximum current for DC bus Imax, 2 times overload, 1 second: 27 A

FWP-50A14F 206047

DC fuse 50 Aeff from the company Cooper Bussmann, type FWP-50A14F

Dimensions: 14 x 51 mm

Rated voltage: 800 V DC

Operating class: aR

The DC fuse can be used for the following loads: 1)

Continuous rated current for DC bus IDC, RMS: 20.5 Aeff

Maximum current for DC bus Imax, 2 times overload, 1 second: 41 A

fuse holder 14 x 51 mm 205829

Fuse holder 14 x 51 mm for hat rail mounting

1)

The actual current value at which the DC fuse triggers, depends on factors such as temperature, duty cycle, the terminal cross sections and can be significantly below the rated value of the fuse.