Liquid cooling system

All KE/KW series modules are designed for mounting on a cold plate with liquid cooling.
The coolant line is connected either on the right side (on the left side only at KW-CP 1000) or on the back using two G1/4" inner threads and the matching hose connections.

 

Cold plate

Technical Data

KW-CP 340(R)

Effective width 340 mm
removable power approx. 1.5 kW

KW-CP 420R

Effective width 416 mm
removable power approx. 1.9 kW

KW-CP 510(R)

Effective width 510 mm
removable power approx. 2.3 kW

KW-CP 680(R)
KW-CP 680(R)-V

Effective width 680 mm
removable power approx. 3.0 kW

KW-CP 1000 *)

Effective width 1000 mm
removable power approx. 3.0 kW

KW-CP 1035R

Effective width 1035 mm
removable power approx. 3.0 kW

R coolant connection on the back
-V   integrated stainless steel piping
*) not to be used for new applications

 

Depending on the module width, the KE/KW cold plate modules can be mounted on the cold plates according to the following table.

When you select the cold plate, you have to take into account the power losses to be removed.

 

Cold plate AMK part no.

Module width / mm

55

85

170

255

425

KW-CP 340

O704

-

-

KW-CP 340R

O705

-

-

KW-CP 420R

O710

-

-

-

KW-CP 510

O706

KW-CP 510R

O707

KW-CP 680

O708

KW-CP 680R

O709

-

KW-CP 680-V

O782

-

KW-CP 680R-V

O783

-

KW-CP 1000 O717

-

KW-CP 1035R

O734

-

-

 

For compact power supplies and compact inverters with a module width of 425 mm, cold plates KW-CP680 ( AMK part no. O708), KW-CP510 (AMK part no. O706) respectively KW-CP510R ( AMK part no. O707) must be exclusively used with a revision from 2.03 on!

 

For more information: see device description Liquid-cooled cold plate KW-CP (AMK part no. 200043)

Use of own cold plates

Requirements on surface when using own cold plate with liquid cooling.