Features

The features of the Profinet Devices are stored in electronic data sheet GSDML.

There are two different GSDML files:

GSDML files are freely available from AMK and are part of the AIPEX PRO programming environment.

The A-SPN option provides the following Profinet-specific features:

 

Features

Values

Communication protocol, participant type

Profinet IO Device Spezifikation V2.3

Conformance Class B

Netload Class

Communication medium

Patch cable of the category CAT5e, shielded

Interfaces

X85/X86, RJ45, Ethernet II, IEEE 802.3
2-port interface with integrated switch functionality

Vendor ID

1379H - AMK GmbH & Co. KG

Device type

4201H:

when configured with GSDML-V2.32-AMK-AX PNS-20160713.xml

4202H:

when configured with GSDML-V2.32-AMK-AX PNS DRV-20160526.xml

Maximum amount of input data

1440 bytes

Maximum amount of output data

1440 bytes

Maximum cable length

50 m

Transfer rates

100 MBit/s

Transfer mode

Half and full duplex

Protocols

  • RTC: Real time Cyclic Protocol, class 1 (unsynchronized), class 3 (synchronized)
  • RTA: Real time Acyclic Protocol
  • DCP: Discovery and Configuration Protocol
  • CL-RPC: Connectionless Remote Procedure Call
  • LLDP: Link Layer Discovery Protocol
  • SNMP: Simple Network Management Protocol
  • MRP: MRP Client is supported

I/O connection type

  • Minimum cycle 1 ms
  • Maximum 255 sub modules per Application Relation (AR)
  • Maximum 1000 sub modules

Supported CIP services
Explicit messages

  • Set_Attribute
  • Get_Attribute
  • Reset services

Predefined standard objects

  • Identity Object
  • Message Route Object
  • Assembly Object
  • Connection Manager
  • Ethernet Link Object
  • TCP/IP Object
  • DLR Object
  • QoS Object

Further properties

  • Reading and writing I&M1-5 (ID34019)
  • DCP, Prioritization and VLAN technology, Shared Device

Topology detection

  • LLDP: Link Layer Discovery Protocol
  • SNMP V1: Simple Network Management Protocol
  • MIB-2: Management Information Base
  • Physical device

 

Analysis network status

The actual network status can be analyzed with the PLC program by the function 'FuiGetNetStatus' (uichannel:=2, uiAxis:=0).

State:

Bit 0 = Profinet IO Device Initialization completed without error (ready for operation)

Bit 1 = not used

Bit 2 = Error

Bit 4 = 'Operational' mode is active

 

See documentSoftware description AmkLibraries (Part no. 205210), AmkBase Bibliothek - Function FuiGetNetStatus (F).