ID530 'Clamping torque'

Sphere of action:

DRIVE

Default value:

1000

Access:

READING / WRITING

Scale:

0.1

Temporarily changeable:

YES

Unit:

% MN

Data length:

2 byte

Min. value:

-

Signed:

NO

Max. value:

-

Format:

DEC

   

List:

NO

   

 

The 'Clamping torque' is effective with the command ID149 'Cmd position stop'. Siehe ID149 'Cmd position stop'.