ID11 'Status class 1-errors'
Sphere of action: |
FORMAL |
Default value: |
0000 0000 0000 0000 |
Access: |
READING |
Scale: |
- |
Temporarily changeable: |
NO |
Unit: |
- |
Data length: |
2 byte |
Min. value: |
- |
Signed: |
NO |
Max. value: |
- |
Format: |
BIN |
|
|
List: |
NO |
|
If an error of the 'Status class 1-errors' is detected in the drive, an error-bit is set in ID11 'Status class 1-errors' and bit 13 in ID135 'Drive status word'. 'Status class 1-errors' and bit 13 in ID135 'Drive status word' can only be reset if there is no longer any error and the command ID99 'Diagnosis reset status class 1' was successfully executed.
Before the controller enable RF is withdrawn internally, the drive attempts to brake the motor to a stop in a regulated manner. If braking cannot take place, the controller enable RF is withdrawn and the motor runs out to stop.
Bit no. |
Condition |
Meaning |
|
---|---|---|---|
0 |
0 |
No error |
|
1 |
Error present:
|
||
1 |
0 |
No error |
|
1 |
Error present: Overtemperature of the converter, shutdown The parameter 'Temperature internal' is longer than the 'Warning time' above the specified threshold value for the device (SEEP device). |
||
2 |
0 |
No error |
|
1 |
Error present: Overtemperature of the motor, shutdown 'Temperature external' is above the threshold value according to ID34166 'Warning time' longer than ID32943 allows 'Temperature sensor motor'.
|
||
3 |
0 |
Reserved |
|
1 |
Reserved |
||
4 |
0 |
No error |
|
1 |
Error present: Supply voltage 24 VDC error |
||
5 |
0 |
No error |
|
1 |
Error present: Error in the encoder signal feedback, e.g. break in the encoder cable or encoder error. |
||
6 |
0 |
Reserved |
|
1 |
Reserved |
||
7 |
0 |
No error |
|
1 |
Error present: Converter overcurrent An unacceptably high converter current was detected, e.g. due to short-circuit or earth contact. |
||
8 |
0 |
No error |
|
1 |
Error present: DC bus overvoltage The DC voltage in the DC bus has exceeded the permissible threshold value. |
||
9-10 |
0 |
Reserved |
|
1 |
Reserved |
||
11 |
0 |
No error |
|
1 |
Error present: Excessive control deviation The difference between the position setpoint and actual position value (ID189 'Following distance') is greater than ID159 'Excess error'. |
||
12 |
0 |
No error |
|
1 |
Error present: Communications error |
||
13 |
0 |
Reserved |
|
1 |
Reserved
|
||
14 |
0 |
Reserved |
|
1 |
Reserved |
||
15 |
0 |
No error |
|
1 |
Manufacturer-specific error present: |