ID1204 'XML file'
Sphere of action: |
INSTANCE |
Default value: |
0 |
Access: |
READING / WRITING |
Scale: |
1 |
Temporarily changeable: |
NO |
Unit: |
- |
Data length: |
1 byte / element |
Min. value: |
- |
Signed: |
NO |
Max. value: |
- |
Format: |
HEX |
Current list length:* |
- |
List: |
YES |
Max. list length:* |
65516 |
* |
The list length is the number of usage data elements without 4 byte head elements. |
AIPEX PRO generates configuration files for some fieldbuses that are stored here.
Instance |
Use |
Interface |
---|---|---|
2 |
EtherCAT (CC) Slave Profinet IO Device Slave EtherNet/IP Slave |
X85 / X86 |
Profibus DP Slave |
X42 / X43 |
|
5 |
1st EtherCAT Master |
X186 |
List element |
Content |
Meaning |
---|---|---|
0 |
x |
List head: Current list length without list head [x byte] (x = n elements x 1 byte / element) |
1 |
65516 |
List head: Maximum list length without list head [byte] |
2 |
e.g. 3C |
Part of the configuration file |
3 |
e.g. 45 |
Part of the configuration file |
... |
... |
... |