0x22C0 'Pulse duty factor motor brake'

Supported hardware:

iX(-R3) / iC(-R3) / iDT5(-R3) /  ihXT / 

Object description

Index

0x22C0

Name

'Pulse duty factor motor brake'

Object type

VAR

Data type

UNSIGNED16

 

The 'Pulse duty factor motor brake' determines the clock ratio TOn/T with which the opened brake is supplied (T = 2 ms, not changeable)

 

This object is used by the following function:

'Controlling motor holding brake'

Entry description

Access

read/write

PDO mapping

no

Range of values

UNSIGNED16

Scaling

1

Unit

%

Default value

0

Min. value

0

Max. value

100