ID34052 'Current path D integral-action time TN'

Sphere of action:

DRIVE

Default value:

0

Access:

READING / WRITING

Scale:

0.1

Temporarily changeable:

YES / NO

Unit:

ms

Data length:

2 byte

Min. value:

0.0 ms

Signed:

NO

Max. value:

300.0 ms

Format:

DEC

   

List:

NO

   

 

ID34052 works in the current controller and is to be derived from the respective type plate or data sheet of the motor.