Technical data
|
Cold plate |
KW-LK110 |
KW-LK250 |
KW-LK400 |
KW-LK500 |
|---|---|---|---|---|
| Part no. |
O745 |
O743 |
O744 |
O802 |
|
Maximum removable power |
120 W |
600 W |
900 W |
1200 W |
|
Ambient temperature |
0 ... 40°C |
0 ... 40°C |
0 ... 40°C |
0 ... 40°C |
|
Fan voltage |
24 VDC ± 10% |
24 VDC ± 10% |
24 VDC ± 10% |
24 VDC ± 10% |
|
Fan flow |
0.3 A |
0.75 A |
1.0 A |
1.5 A |
|
Cable length |
300 mm |
300 mm |
300 mm |
300 mm |
|
Protection class |
IP 20 2) |
IP 20 |
IP 20 |
IP 20 |
|
Dimensions |
108 x 46 x 418 mm |
260 x 85 x 465 mm |
410 x 85 x 465 mm |
510 x 85 x 465 mm |
|
Cooling surface (B x H) |
105 x 320 mm |
250 x 320 mm |
400 x 320 mm |
500 x 320 mm |
| Effective width in case of through-hole mounting |
-- |
220 mm |
370 mm | 470 mm |
|
Weight |
about 2 kg |
about 10 kg |
about 16 kg |
about 19 kg |
| 1) |
24 VDC must be supplied externally |
|
2) |
Mounted on mounting plate in the switch cabinet (See 'Mounting KW-LK110'.) |