Mains chokes ALN xx

Designation

ALN 12

ALN 17

ALN 36

ALN 36 / 1000

ALN 63

Nominal voltage UN

3 x 500 V, 50 / 60 Hz*

Nominal current IN

3 x 12 A

3 x 17 A

3 x 36 A

3 x 36 A

3 x 63 A

Maximum current [rms]

30 A for 20 s

(2.5 x IN)

54 A for 60 s

(3.17 x IN)

54 A for 60 s

(1.5 x IN)

100 A for 60 s

(2.77 x IN)

94 A for 60 s

(1.5 x IN)

Short circuit voltage uk

4 % at 50 Hz

3.9 % at 50 Hz

4 % at 50 Hz

4 % at 50 Hz

4 % at 50 Hz

Inductance/Line

3 mH

2.1 mH

1 mH

1 mH

0.58 mH

Power loss

50 W

60 W

80 W

80 W

120 W

Protection class

IP 00

Weight

3.6 kg

4 kg

6 kg

7 kg

10 kg

Dimensions

Siehe 'Mains chokes ALN 12 ... ALN 150 / ALN 15-SI ... ALN 90-S'.

AMK part no.

O911

O742

O726

O727

O728

Designation

ALN 85

ALN 125

ALN 150-2,5

ALN 180

ALN 270

Nominal voltage UN

3 x 500 V, 50 / 60 Hz*

Nominal current IN

3 x 85 A

3 x 125 A

3 x 150 A

3 x 180 A

3 x 270 A

Maximum current [rms]

127 A for 60 s

(1.5 x IN)

187 A for 60 s

(1.5 x IN)

300 A for 60 s

(2 x IN)

330 A for 60 s

(1.83 x IN)

480 A for 60 s

(1.77 x IN)

Short circuit voltage uk

4 % at 50 Hz

4 % at 50 Hz

2.5 % at 50 Hz

2 % at 50 Hz

4 % at 50 Hz

Inductance/Line

0.43 mH

0.295 mH

0.15 mH

0.125 mH

0.137 mH

Power loss

180 W

210 W

300 W

300 W

425 W

Protection class

IP 00

Weight

16 kg

20 kg

27 kg

27 kg

62 kg

Dimensions

Siehe 'Mains chokes ALN 12 ... ALN 150 / ALN 15-SI ... ALN 90-S'.

Siehe 'Mains chokes ALN 180(-S)'.

Siehe 'Mains choke ALN 270'.

AMK part no.

O729

O730

O731

O739

O965

* IT network: Voltage range is restricted here to
3 x 400 V -20%... 440 V + 10 %, 47 ... 63 Hz